Page 4 of 9
Output sub assembly: (included)
. Uses 2 Channel output cards (6-circuit), 900 watts maximum per channel (Green/Yellow/Red output).
. Up to 8 cards in a row to provide a full 16-phase configuration per rack.
. Includes two slots for standard NEMA TS2 BIU’s one slot at each end of the rack (BIU’s not included).
. 5-amp Dual circuit Flasher Unit with manual flashing frequency selection (1Hz standard).
. 6 dual circuit Flash Transfer Relays included.
. Selectable Red/Yellow flash per flash output (all Yellow Flash standard).